Protherm Indoor

//Protherm Indoor

Protherm Indoor

Protherm Indoor

The growing need for energy consumption to be reduced has lead to the creation of  high efficient air conditioners, whilst maintaining sturdiness, reliability and compactness, as happens with Protherm Indoor air conditioner for electrical enclosures.

CVE air conditioners, for Indoor applcations, are characterised by a smart design, a display for the information visualisation (except CVE03) and a condensate dissipating device (from CVE11 and CVE07S).

Thanks to the introduction of new components and of SEM and SEM² is possible to obtain up to 23% of energy saving, with an increase of the air conditioner’s cooling capacity.

Several installations
For Indoor electrical enclosures (Protherm Indoor CVE) and for Outdoor cabinets (Protherm Outdoor CVO)

Cooling Capacity
Wide range of cooling capacity: from 360W to 5600W, the largest range available on the market, with 9 available sizes

Wide choice of power supplies
The units are available in 115V, 230V e 400V/460V

Extended operating range
Protherm units can work in ambient with temperature between +20/+55 (CVE), -20/+55 (CVO, CE), -40 (CVO, UL)

Certifications

ISO 9001
ISO 14001
ISO 50001
UL Certificate
EAC Air Conditioner
Certificate F.GAS

    Information pursuant to art. 13 of the European Regulation on the processing of personal data (GDPR - Reg. U.E. 679/16)

    Pursuant to art. 13 of EU Regulation 679/16 the following information is provided on the processing that may take place following the compilation and submission of the data in the form you are about to fill out. The data present in the form will be used to answer the questions formulated. You can consult the complete information on this link

    *Name and Surname

    *Email

    *Country

    *Your message

    I accept the Privacy


    Version Cooling CapacityPower SupplyDimensions
    CVE03002200000360-380230-1-50/60443x324,5x206
    CVE03U12030000380115-1-60443x324,5x206
    CVE03U12200000380230-1-50/60443x324,5x206
    CVE05002208000550-580230-1-50/60642x314,5x223
    CVE05002288000500-550400-2-50 460-2-60642x314,5x223
    CVE0500212800050048VDC642x314,5x223
    CVE05U12038000580115-1-60642x314,5x223
    CVE05U12208000580230-1-50/60642x314,5x223
    CVE0700S208000800-850230-1-50/60550x279x286
    CVE08002208000850-900230-1-50/60642x314,5x223
    CVE08002288000800-850400-2-50 460-2-60642x314,5x223
    CVE08U12038000900115-1-60642x314,5x223
    CVE08U12208000900230-1-50/60642x314,5x223
    CVE110022080001100-1150230-1-50/60913x413x248
    CVE110022880001050-1100400-2-50 460-2-60913x413x248
    CVE11U120380001150115-1-60913x413x248
    CVE11U122080001150230-1-50/60913x413x248
    CVE150022080001500-1600230-1-50/60913x413x248
    CVE150022880001400-1500400-2-50 460-2-60913x413x248
    CVE15U120380001600115-1-60913x413x248
    CVE15U122080001600230-1-50/60913x413x248
    CVE15U126280001500400-3-50 460-3-601005x413x263
    CVE1500S2080001500-1600230-1-50/60950x400x304
    CVE1500S6180001400-1500400-3-50 460-3-60950x400x304
    CVE200022080002100-2200230-1-50/601005x413x263
    CVE200026180002000-2100400-3-50 460-3-601005x413x263
    CVE20U120380002200115-1-601005x413x263
    CVE20U122080002200230-1-50/601005x409x263
    CVE20U126280002100400-3-50 460-3-601005x413x263
    CVE2500S2080002550-2750230-1-50/601580x400x305
    CVE2500S6180002400-2600400-3-50 460-3-601580x400x305
    CVE300022080003000-3150230-1-50/601219x514x347,5
    CVE300026180002850-3000400-3-50 460-3-601219x514x347,5
    CVE30U122080003150230-1-50/601219x514x347,5
    CVE30U126280003000400-3-50 460-3-601219x514x347,5
    CVE400022080004000-4100230-1-50/601219x514x347,5
    CVE400026180003950-4050400-3-50 460-3-601219x514x347,5
    CVE40U122080004100230-1-50/601219x514x347,5
    CVE40U126280004050400-3-50 460-3-601219x514x347,5
    CVE600026180005600-5950400-3-50 460-3-601406x556x403
    CVE60U126280005950400-3-50 460-3-601406x556x403