Modern electric enclosures and servers need a very accurate temperature control and a low energy consumption, even with variable heat loads. While in the past these two requirements were incompatible and only partially satisfied, they are now both available in the new FLEX IN CDI with Inverter technology.

Cooling capacity
With three models, the Flex In covers a wide range of cooling capacity, from 1000W to 4200W.
Several installations for each need of space
The Flex In can be installed in external, semi-flush or flush configuration.
Wider range of power supply voltage
A code for whole monophase range: 110 ÷ 240 V, 50 ÷ 60Hz.
Wide operating range
Flex In can work in ambient with temperature from 10°C to 60°C, the largest range available on the market. Set point regulation from 20°C to 45°C.
Certifications
CE, UL Listed and EAC, ready for the export to all country in the world.

Connectivity 4.0
In a point of view of Industry 4.0, an Ethernet port is integrated on the controller of the air conditioner. It allows the monitoring of all relevant parameters of the unit (temperatures, working modes, alarms) by http, SNMP protocols.

Informativa ai sensi dell’art. 13 del Regolamento Europeo sul trattamento dei dati personali (GDPR – Reg. U.E. 679/16)

Ai sensi dell’art. 13 del Regolamento UE 679/16 le vengono fornite le seguenti informazioni sul trattamento che potrà avere luogo a seguito della compilazione e dell’invio dei dati presenti nel modulo che state per compilare. I dati presenti nel modulo saranno utilizzati per rispondere ai quesiti formulati. Potete consultare l'informativa completa a questo link

*Nome e Cognome

*Email

*Regione

*Il tuo messaggio

Accetto le condizioni sulla Privacy


UL Certification
The UL for our products can be downloaded directly on the UL website at the following link:
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
In the search form, insert stulz spa in the comapy name box.
It will appear a list of the downloadable documents.

Dati Tecnici Flex_In

wdt_IDVersionePotenza Frigorifera L35L35 DIN EN 14511 (W)Potenza frigorifera L35L50 DIN EN 14511 (W)Dimensioni (mm) HxWxDScheda TecnicaDimaLayoutGrafico Resa
1 CDI20 2.000 1350 1666x454x294 Scheda Tecnica Dima Layout
2 CDI 26 2.600 2100 1666x496x294 Scheda Tecnica Dima Layout
3 CDI 40 4.200 3350 1666x496x393 Scheda Tecnica Dima Layout
wdt_IDVersionePotenza Frigorifera L35L35 DIN EN 14511 (W)Potenza frigorifera L35L50 DIN EN 14511 (W)Dimensioni (mm) HxWxDScheda TecnicaDimaLayoutGrafico Resa